Readers' letters Series We were delighted that the products ordered on Friday arrived. I saw him immediately to replace the traditional art izzóimat Led light bulbs. When replacing the large part I had no problems. Unfortunately there is problems. The E14 bulbs When installing each of them found that they unfortunately turned off, dimmed, but will illuminate. I tried swapping them, but unfortunately it did not bring results. The E27 is also coded with the same problem ...
At the same time certainly agree - something only lights up when receiving power because of anything you can not - although it would be just really good. So if you are disconnected condition is poorly lit, the LEDs glow, it certainly is the leakage current apartment. It is possible, for example, monorail simpsons was inattentive monorail simpsons and the connection is not interrupted by the phase of the light switch, but zero. So the lights are switched off mode power. The current passing through the lamp on the neutral side of the switch, and there is broken (you have switched off). Yes, but the interrupted neutral monorail simpsons piece that acts as a capacitor in addition to the phase when the phase is positive, monorail simpsons then the negative voltage wire piece is generated and vice versa. So, the bulb up to 100 200Voltos induced power can get disconnected state. It is true the current is low, so it can not be operated at full power the LED light, the only glitch. The solution is to be equipped with the lights properly, that is, the phase of the light switch must be interrupted, rather than zero, because it is so it can be life-threatening.
Of course, if there so you stray current situation was before, monorail simpsons it's not just a traditional monorail simpsons izzónál because they can be a traditional bulb, more power, monorail simpsons LED and low energy consumption and thus more sensitive to kóboráramra.
Not all LED light indicates the stray currents, which is because they are designed, for example: 220-240volt work, but that they are such that between 85 265Volt. For major power generation is one of the more glitter, the other less so.
Answer: Thanks for the comprehensive answer. A little monorail simpsons scared when ordered to do very little amount of LED light bulbs not functioned monorail simpsons as should have been expected. I consulted with my electrician, who I feel that is among the best, and he has provided a possible solution to the problem. The connections were all taken in accordance with the regulations. As there are many places to attributive (light) switch is (Prodax Archus), so the cause of the problem was that the power required for the return signal is passed through the bulb, and it is caused by the illumination of the light bulbs. I removed the switch from the feedback unit, so the problem is completely gone. No flashing, no light no light can be observed. Thanks for your help In addition, the other bulbs in the house I turn in my order today.
Answer: I became wiser, I had not thought of that. Accordingly, the switch will illuminate when the light is turned off. I also have two places Prodax equipped with glow lamps, for me it just can not happen because monorail simpsons I will illuminate the switch when the electricity is turned up. And the way to work, I had to zero leads to the switch. Your version can be solved without zero records back then were no plans for the LED. To think so would not have had brought to zero, respectively. would have to switch to other deposits that the light is not in the current light source to go through.
István Székely solution proposal: The problem of the chandelier or luminaire terminals, in parallel with the lamp 220-330nF/400V-os not solve electrolytic capacitor connection. This shunt with LED lights and ample power to the lamp is Glimm.
What do they know about LED bulbs and what not? To grief involved for 100Wattos banning incandescent bulbs - if ... When we choose the right energy saving point of view? Uncertainties in LED lights and ROI What determines the reliability of an LED lamp lifetime? Warm white, medium white, cool white LED RGB LED color temperature information
The design of the variable-color RGB LED RGB LED color light therapy Power RGB LED spotlight - színszabályozós LED RGB LED strip lighting - LED lighting design monorail simpsons színszabályozós running RGB LED strip light color LED lighting special frequency
Comparative tests GU5.3 LED spotlight MR16 12V power socket head LED spots comparative tests with E27 socket LED pears comparative tests of E14 (candle monorail simpsons mignon) socketed LED lamps with GU10 socket comparative tests of LED spots comparative tests of socket G9 LED lamps comparative tests LED GX53 socket monorail simpsons bútorspotok comparative tests G4 LED 12V power socket and mini corn bútorspotok comparative tests
Recent Entries Life Light Series 24pcs 2835 SMD LEDs mounted LED spot. :) I love the LED lights are applying to replace a compact fluorescent LED fluorescent lamp